Two review findings.
The stored-token refresh path (`refreshStoredAuthToken`) calls SDK discovery
directly rather than through `InspectorClient.effectiveAuthFetch`, so a state
file holding a refresh token and client information but no `serverMetadata`
still hit the upstream OIDC-schema failure and could not refresh against the
very servers this change is for. Its default `discover` now wraps the global
fetch with the compat shim; a caller-supplied `fetchFn` is left alone. Covered
by a test that injects no `discover` — injecting one would bypass the default
under test — against a real server that 404s the RFC 8414 path and serves plain
RFC 8414 metadata at the appended OIDC path.
`oidcDiscoveryCandidates` matched the well-known path by bare prefix, so it
also claimed `/.well-known/oauth-authorization-server-backup` and would have
replaced that path's failed response with a document fetched from a derived
URL. It now requires the exact path or a `/` boundary, which is precisely the
set `buildDiscoveryUrls` can emit.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UL9retfvAXRgvi6EWk4SY4
Signed-off-by: cliffhall <cliff@futurescale.com>